Carlo Gavazzi’s RVEFA 120040 acclaimed Electro-Product of the Year 2009 in Drives & Control

ELECTRO-PRODUCT OF THE YEAR 2009
On February 19th at the Marriott Hotel, Warsaw, prizes were handed out to the winners of the seventh (2009) edition of the ELECTRO-PRODUCT OF THE YEAR competition.

In the Drives & Control category, readers of the Elektrosystemy magazine voted for the RVEFA 120040 inverter from Carlo Gavazzi

RVEFA120040 0.4 kW, 0.50 HP
• AC variable speed drive for induction AC motors
• Sensorless vector or V/F control, high starting torque
• Supply voltage: 1-ph 200-240VAC
• Conforms to EMI radio standard and EMS immunity standard. EN 61800-3 for the second environment (Industrial sites).
• All parameters available both from the keypad and from a PC
• RS232 or RS- 485MODBus RTU/ASCI serial communications available on all models through an option card
• Speed control with buttons and knob
• 8-step speed adjustment
• Copy card option for fast and easy setup of identical drives
• I/O expansion (2 IN / 1 OUT expandable)
• DIN rail mounting or panel mounting, remote keypad also available











One-phase and three-phases energy meter with LCD data displaying

One-phase and three-phases energy meter with LCD data displaying; indicated for active energy metering. Housing for DIN rail mounting, IP40 (front) protection degree. Direct connection up to 64 A. Moreover the meter can be provided with pulse output proportional to the active energy being measured. Energy measurements: total kWh. Self power supply . Dimensions: one module for one-phase and four modules for three-phases. 1 pulse output on request.
TRMS measurements of distorted sine waves (voltages/currents)
Certified according to MID



New Motor Controllers from 0,44 kW to 55,0 kW

Variable Frequency AC DrivesVariflex2 RVCF

• AC variable speed drive for AC induction motors
• Sensorless vector control or V/F mode, high starting torque
• Input voltage range: 1-ph. 230 VAC, 3-ph. 230 VAC, 3-ph. 480 VAC
• Compliance with EMI and EMS immunity standards for class 2 environments
(industrial setting) and EN 61800-3
• All parameters are available both via a keypad and a PC
• Serial communication RS232 or RS485MODBus RTU/ASCI available on all models via optional cards
• Knobs and pushbuttons for speed control
• Copying cards for fast and easy setup of identical drives
• PID function available and optional EMC filter
• Memory stick(Copy card) option for fast andaccurate drive to drive parameter transfer and storage
• NPN/PNP digital inputs
• DIN-rail mounting or panel mounting, remotely-controlled keypad also available



Carlo Gavazzi – now also signal columns

Carlo Gavazzi has expanded its product line to include a wide range of modular signal columns. This rich offer includes AC/DC powered light and acoustic tower beacons, for either vertical or horizontal installation.
Devices with static, pulsed and strobe light are offered. Available colours: red, yellow, green, blue and white. Acoustic elements consist of buzzers or sounders with static or variable modulation.
All tower beacons from Carlo Gavazzi are UL, CSA and CE certified.



Carlo Gavazzi has launched a new time relay

Carlo Gavazzi has launched a new time relay featuring:
- 32 independent time settings
- time settings from 01s to 100h
- PC programmable
- width 17.5 mm
- power supply: 24VDC and 24-20VAC
- DIN rail mounted
- compliant to European standards



New analyzer from Carlo Gavazzi, WM5-96

The need to register and measure power consumption of either individual devices or complex power systems requires special meters to be installed. For such applications the analyzers from Carlo Gavazzi are virtually perfect. Following market demand, a new device, labelled WM5-96, has been developed based on the previous model, the WM4-96. The new analyzer is unique in allowing data to be transmitted through a new optical port installed on the device’s front panel. Technological parameters have been improved with regard to voltage (600kV) and current (60kA) analysis. The system allows for direct measurement of currents up to 10A and uses a measuring transformer for higher values. Direct communication with the device is ensured through an Ethernet port or alternatively an RS 485 or RS 232 bus. This analysis can be performed using the PowerSoft software. To meet the increasing market requirements the program is constantly updated. Analyzed data can be stored on a server or on a 2MB memory card, which unfortunately is a considerably limitation of possible applications for the RS485 model ( signals are paired on the same slot.



Anemometers

Anemometers and relative anemometers are used to measure the speed and the relative direction of the wind.
Applications include wind turbines, buildings, cranes, weather stations, green-houses and more.
Anemometers are equipped with PNP and NPN outputs, in which a fixed current is switched proportionally to the air speed at the rate of 10 pulses per m/s. Wind vanes registers deviations in the wind direction (left/right) from a given starting point.
Both devices are equipped with heaters to reduce the risk of glazing and also feature custom-designed protection mechanisms for the protection of bearings and electronic parts against dirt and humidity.